  Keithley 2001 repair 76 Collapse all/Expand all
273 Support Closed Normal Buy components for repair tin 07/30/2012 Actions
274 Bug Closed Normal K2 : ERROR 401.1 - Signal switching; zero cal switch tin Actions
275 Bug Closed Normal K2 - Error 402.1 - Frequency switch tin Actions
276 Bug Closed Normal ERROR 404.1 – Absolute value (x1 gain); -full-scale DAC output tin Actions
277 Bug Closed Normal K2 - ERROR 405.2 – Absolute value x10 gain comparison; large +DAC output tin Actions
278 Feature Closed Normal D2 - checks Actions
279 Feature Closed Normal Schematics RE - analog board tin 07/31/2012 Actions
281 Feature Closed Normal Display board move to unit #4 tin Actions
282 Rework Closed Normal Install display board tin Actions
283 Rework Closed Normal No response from analog board tin Actions
284 Rework Closed Normal Test digital board. tin Actions
285 Rework Closed Normal All functions and all ranges "Overflow" tin 08/05/2012 Actions
286 Feature Closed Normal Calibrate unit (Tektronix calibration) tin 01/19/2014 Actions
288 Bug Closed High K4 - repair status. tin 02/28/2015 Actions
294 Feature Closed Normal Read and decode firmwares for 2001 DMMs tin 08/10/2012 Actions
297 Feature Closed Normal Finish ADC board schematics. tin 12/11/2012 Actions
342 Bug Closed Normal Fix FE section on analog board tin 09/09/2012 Actions
343 Bug Closed Normal Send K2001 #5 to iZerg Izerg 10/31/2012 Actions
535 Bug Closed Normal AC voltage select unit fails tin 10/21/2012 Actions
637 Support Closed Normal Review 2001's inventory tin 02/16/2014 Actions
641 Feature Closed Normal Finish AC input block schematics tin 12/18/2012 Actions
642 Feature Closed Normal Voltage reference block schematics recovery tin 12/17/2012 Actions
647 Feature Closed Normal Cook transformer in paraffin to avoid buzzing Izerg 12/17/2012 Actions
650 Feature Closed High ADC board Izerg Actions
652 Bug Closed Normal Fix AC input mains curcuitry, replace electrolytic capacitors, replace transformer tin 12/31/2012 Actions
658 Bug Closed Normal Fix 401.1 - Signal switching; zero cal switch tin 01/13/2013 Actions
816 Support Closed Normal Schematics recovery for analog board Keithley 2001 tin 07/21/2014 Actions
817 Support Closed Normal Схема платы A/D (Keithley 2001-162-01G) tin 10/03/2013 Actions
818 Support Closed Normal Schematics for analog board (Keithley 2001-102-04L) Izerg 07/21/2014 Actions
819 Support Closed Normal Cхема платы передней панели tin 10/08/2013 Actions
820 Support Closed Normal Schematics for digital board (Keithley 2001-142-06H) tin 10/31/2013 Actions
839 Feature Closed Low analog board photo tin 10/26/2013 Actions
840 Support Closed Normal 3 ADC modules shipped, receive and test rest units tin 11/09/2013 Actions
852 Feature Closed Normal LabView control panel development tin 02/28/2014 Actions
854 Bug Closed Normal Fix error 402.1 - Signal switching; frequency switch tin 12/14/2013 Actions
855 Bug Closed Normal Fix error 403.1 – Signal switching; ground switch tin 12/21/2013 Actions
856 Bug Closed Normal Fix error 412.1 – AC amps switch tin 12/28/2013 Actions
858 Bug Closed Normal VFD Power supply issues? tin Actions
859 Feature Closed Normal Схема аналоговой платы (Keithley 2001-102-04J) tin 07/11/2014 Actions
862 Bug Closed Normal Fix errors 404.1, 404.2, 404.3, 404.4, 404.5 - Absolute value (x1 gain); tin 12/22/2013 Actions
863 Bug Closed Normal Fix errors 405.2, 405.4, 405.6, 405.8, - Absolute value x10 gain comparison tin 12/22/2013 Actions
864 Bug Closed Normal Fix error 406.6 – Voltage comparison tin 12/22/2013 Actions
865 Bug Closed Normal Fix errors 407.1, 407.2, 407.3 - Front end 2V/200V/750V tin 12/22/2013 Actions
866 Bug Closed Normal Fix error 409.6 – ÷750 correction factor; signal comparisons tin 12/22/2013 Actions
867 Bug Closed Normal Fix error 410.1, 411.1, 411.2 - TRMS / TRMS Filter tin 12/29/2013 Actions
868 Feature Closed Normal Assembly meter for function checks. tin 12/15/2013 Actions
869 Feature Closed Normal Spec test tin 12/15/2013 Actions
871 Bug Closed Normal Replace C108 capacitor tin 12/31/2013 Actions
879 Bug Closed Normal Issue list update tin Actions
884 Feature Closed Normal UART protocol between front panel board and digital board. tin Actions
(101-150/307) Per page: 50, 100, 200, 500