1160 Keithley 2000 Support Closed Normal Backup EEPROM with programm memory A02 tin Actions
1158 Keithley 2000 Feature Closed Normal Broken K2000 unit received, need repairs tin Actions
1193 Keithley 2000 Feature Closed Normal Buy parts for repair tin 05/30/2015 Actions
1178 Keithley 2000 Feature Closed Low Check components on K2000 unit tin Actions
1159 Keithley 2000 Rework Closed Normal Clean board and restore damaged traces from leaked electrolyte tin 09/22/2014 Actions
874 Keithley 2000 Feature Closed Normal Keithley 2000 schematics tin 12/23/2013 Actions
840 Keithley 2001 repair Support Closed Normal 3 ADC modules shipped, receive and test rest units tin 11/09/2013 Actions
895 Keithley 2001 repair Feature Closed Normal 304.x series self-test errors (Ohm) Izerg 01/05/2014 Actions
535 Keithley 2001 repair Bug Closed Normal AC voltage select unit fails tin 10/21/2012 Actions
285 Keithley 2001 repair Rework Closed Normal All functions and all ranges "Overflow" tin 08/05/2012 Actions
868 Keithley 2001 repair Feature Closed Normal Assembly meter for function checks. tin 12/15/2013 Actions
273 Keithley 2001 repair Support Closed Normal Buy components for repair tin 07/30/2012 Actions
286 Keithley 2001 repair Feature Closed Normal Calibrate unit (Tektronix calibration) tin 01/19/2014 Actions
956 Keithley 2001 repair Feature Closed Normal Calibration constants for K2001 units tin 02/15/2014 Actions
819 Keithley 2001 repair Support Closed Normal Cхема платы передней панели tin 10/08/2013 Actions
278 Keithley 2001 repair Feature Closed Normal D2 - checks Actions
281 Keithley 2001 repair Feature Closed Normal Display board move to unit #4 tin Actions
1188 Keithley 2001 repair Feature Closed Normal Dump firmware B17 from 2001M tin Actions
276 Keithley 2001 repair Bug Closed Normal ERROR 404.1 – Absolute value (x1 gain); -full-scale DAC output tin Actions
641 Keithley 2001 repair Feature Closed Normal Finish AC input block schematics tin 12/18/2012 Actions
297 Keithley 2001 repair Feature Closed Normal Finish ADC board schematics. tin 12/11/2012 Actions
658 Keithley 2001 repair Bug Closed Normal Fix 401.1 - Signal switching; zero cal switch tin 01/13/2013 Actions
652 Keithley 2001 repair Bug Closed Normal Fix AC input mains curcuitry, replace electrolytic capacitors, replace transformer tin 12/31/2012 Actions
342 Keithley 2001 repair Bug Closed Normal Fix FE section on analog board tin 09/09/2012 Actions
854 Keithley 2001 repair Bug Closed Normal Fix error 402.1 - Signal switching; frequency switch tin 12/14/2013 Actions
855 Keithley 2001 repair Bug Closed Normal Fix error 403.1 – Signal switching; ground switch tin 12/21/2013 Actions
864 Keithley 2001 repair Bug Closed Normal Fix error 406.6 – Voltage comparison tin 12/22/2013 Actions
866 Keithley 2001 repair Bug Closed Normal Fix error 409.6 – ÷750 correction factor; signal comparisons tin 12/22/2013 Actions
867 Keithley 2001 repair Bug Closed Normal Fix error 410.1, 411.1, 411.2 - TRMS / TRMS Filter tin 12/29/2013 Actions
856 Keithley 2001 repair Bug Closed Normal Fix error 412.1 – AC amps switch tin 12/28/2013 Actions
862 Keithley 2001 repair Bug Closed Normal Fix errors 404.1, 404.2, 404.3, 404.4, 404.5 - Absolute value (x1 gain); tin 12/22/2013 Actions
863 Keithley 2001 repair Bug Closed Normal Fix errors 405.2, 405.4, 405.6, 405.8, - Absolute value x10 gain comparison tin 12/22/2013 Actions
865 Keithley 2001 repair Bug Closed Normal Fix errors 407.1, 407.2, 407.3 - Front end 2V/200V/750V tin 12/22/2013 Actions
890 Keithley 2001 repair Support Closed Normal Install DS1245Y for MEM2 option tin 01/04/2014 Actions
282 Keithley 2001 repair Rework Closed Normal Install display board tin Actions
879 Keithley 2001 repair Bug Closed Normal Issue list update tin Actions
277 Keithley 2001 repair Bug Closed Normal K2 - ERROR 405.2 – Absolute value x10 gain comparison; large +DAC output tin Actions
275 Keithley 2001 repair Bug Closed Normal K2 - Error 402.1 - Frequency switch tin Actions
272 Keithley 2001 repair Support Closed Normal K2 - repair status. tin Actions
268 Keithley 2001 repair Bug Closed Normal K2 : ERROR 105.2 - System trigger bus tin 07/22/2012 Actions
271 Keithley 2001 repair Feature Closed Normal K2 : ERROR 304 Section tin Actions
269 Keithley 2001 repair Bug Closed Normal K2 : ERROR 304.6 - Ohms sources; 70nA and 770nA tin Actions
270 Keithley 2001 repair Bug Closed Normal K2 : ERROR 304.7 - Ohms sources; 4.4nA and 770nA tin Actions
274 Keithley 2001 repair Bug Closed Normal K2 : ERROR 401.1 - Signal switching; zero cal switch tin Actions
288 Keithley 2001 repair Bug Closed High K4 - repair status. tin 02/28/2015 Actions
885 Keithley 2001 repair Feature Closed Normal Keithley 2001 thermal evaluation tin 01/01/2014 Actions
852 Keithley 2001 repair Feature Closed Normal LabView control panel development tin 02/28/2014 Actions
283 Keithley 2001 repair Rework Closed Normal No response from analog board tin Actions
294 Keithley 2001 repair Feature Closed Normal Read and decode firmwares for 2001 DMMs tin 08/10/2012 Actions
1184 Keithley 2001 repair Bug Closed Normal Repair status tin Actions
(51-100/230) Per page: 50, 100, 200, 500