Project

General

Profile

Feature #1296

Test with different mains

Added by tin about 7 years ago. Updated about 7 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Target version:
Start date:
01/05/2016
Due date:
% Done:

0%

Estimated time:

Description

AC input test, self-test result after cal

AC source: Chroma 61504

110VAC, 60Hz - PASS, P=26.5W, 0.3A, PF = 0.77
230VAC, 50Hz - PASS, P=22.5, 0.17A, PF = 0.77
90VAC, 400Hz - FAIL1, P=17W, 0.23A, PF = 0.8
250VAC, 400Hz - PASS, P=25.5W, 0.11A, PF = 0.92A

90VAC 132VAC 180VAC 250VAC
50Hz PASS PASS PASS PASS
60Hz PASS PASS PASS PASS
400Hz FAIL1 PASS FAIL2 PASS

FAIL1 = 302.4 ADGND MUX, 303.1 Input buffer, 304.1, 304.2 Open ckt ohms, 305.4 20V MUX, 306.1, 306.2 Ohms
Ohms shows 0.43 Gohm
FAIL2 = 304.1, 304.2 Open ckt ohms, 305.4 20V MUX

#1

Updated by tin about 7 years ago

  • Description updated (diff)

Also available in: Atom PDF