Feature #1070
Initial inspection
Description
Receive unit and initial inspection and condition check.
Files
Updated by tin almost 9 years ago
- Status changed from New to In Progress
- % Done changed from 0 to 50
Battery cover/holder damaged
Blown PNP BJT 2SA2023 on DC-DC board
Fuse on DC in board ok
Updated by tin almost 9 years ago
- File d3w.jpg d3w.jpg added
- File _DSC5980.JPG _DSC5980.JPG added
- Target version set to D3 Repair
- % Done changed from 50 to 80
PNP replaced.
Camera powers on correctly.
Mirror mechanism locking up from time to time.
Updated by tin almost 9 years ago
- File D3-1.jpg D3-1.jpg added
- File D3-1-2.jpg D3-1-2.jpg added
- File D3-1-3.jpg D3-1-3.jpg added
Updated by tin almost 9 years ago
- Status changed from In Progress to Closed
- % Done changed from 80 to 100