Feature #1068

Wire-wound precision resistors samples

Added by tin almost 5 years ago. Updated over 4 years ago.

Status:In ProgressStart date:17/04/2014
Priority:NormalDue date:
Assignee:tin% Done:

50%

Category:-
Target version:prototype

Description

MFG Part number Resistance value Tolerance TC Qty Note
Fluke 142349 100K 0.1% 6
Fluke 156448 250K 0.05% 3 13 +25..+55c,2W,140x375 mils
Fluke 156455 50K 0.1% 5 2 +25..+55c,1W,750x750 mils
Fluke 145128 EM3 ? 0.1% 2
Fluke 131664 10K 0.1% 8 +25c,1W
Fluke ? ? ? 3
Fluke 145708 5K 2
Fluke 146530 40K JL3 N2 0.02% 5 2 -55..+275c,0.5W,750x875 mils

http://www.justnsnparts.com/rfq.aspx?id=156448&mfr=fluke-corporation&nsn=5905002413460

FLUKE 146159 320.000 0.1% 5 +105c, 0.5W, 688x562 mils
FLUKE 111906 2.5317K 0.05% 5 -55..+125c,0.5W,1500x500 mils
FLUKE 131953 1.600K 0.01% 10 -55..+135c,0.125W, 750x750 mils
FLUKE 112060 28.571K 0.05% 5 +25c,0.5W, 500x562 mils
FLUKE 199802 9.898K 0.02% 1W
VPG VPR5 391342 1.0000R 0.1% ± 10 ppm/°C (Below 10R) 7 5W, 300V, Kelvin connect

vpr5vpr7.pdf (260 KB) tin, 28/04/2014 09:56

FR-4118.jpg (5.76 MB) tin, 28/04/2014 22:10

FR-4136.jpg (5.4 MB) tin, 28/04/2014 22:10

FR-4148.jpg (5.11 MB) tin, 28/04/2014 22:10

History

#1 Updated by tin almost 5 years ago

  • Description updated (diff)

#2 Updated by tin over 4 years ago

  • % Done changed from 0 to 50
  • File vpr5vpr7.pdf added
  • Description updated (diff)
  • Category set to 107
  • Status changed from New to Resolved
  • Assignee set to tin
  • Target version set to prototype

#3 Updated by tin over 4 years ago

#4 Updated by tin over 4 years ago

  • Status changed from Resolved to In Progress

Some resistors need repair

1 x 100k, 2 x 40K, 2 x 10K, 9 x 250K

#5 Updated by tin over 4 years ago

1 x 250K fixed
1 x 10K fixed